AC to DC Power Supply HVDC-DC Module

Looking for an efficient AC to DC power supply? Check out our HVDC-DC Module! We are a factory specializing in manufacturing high-quality power supply solutions.

Request a Quote
  • AC to DC Power Supply HVDC-DC Module
  • AC to DC Power Supply HVDC-DC Module

PRODUCTS DETAILS

The rated output power is 900 W. The PSU is hotswappable, equalizes current, and supports 1+1 or 2+2 parallel connection. The PSU supports PMBus communication, and sends the PSU information to the system to facilitate monitoring and management. Features ● fficc 94% (Vin = 230 V AC, Pout = 450 W, TA =25°C, without a fan) ● Depth x Width x Height: 183.0 mm x 68.0 mm x40.5 mm ● Power grid: 110 V AC/220 V AC single-phase, 240 VDC ● Supports AC input protection for undervoltage,overvoltage, overcurrent, short circuit, and PFC overvoltage ● Supports HVDC input protection for overvoltage,undervoltage, and PFC overvoltage ● Supports output protection for overvoltage,overcurrent, short circuit, and overtemperature ● I2C for control, programming, and monitoring ● CE, UL, TUV, CCC, BSMI, BIS cfic and CB report available ● 80 Plus platinum energy fficc cfic ● IEC 60950-1, EN 60950-1, UL 60950-1, GB 4943.1,IEC 62368-1 ● RoHS compliant Applications: Server The PSU can withstand an input voltage of 318 V AC for 48 hours (non-working state is acceptable). The inrush current should meet the requirements in ETSI EN 300 132-3. When testing the maximum input current, ensure that the voltage of the power input port meets the requirement and that the output is 900 W. Current Share Design Requirements 1. Supports 1+1 or 2+2 mode. Current sharing only in MV12 mode. 2. The total load at startup in parallel operation scenarios should be less than the rated load of a single PSU. 3. When PSUs work in 1+1 or 2+2 mode, if one of the PSUs works in MV6 mode and other PSUs work in MV12 mode, the PSUs should work properly without ffc each other. 4. In scenarios where ff PSUs are not installed together, the I-MON signals of the two PSUs should not ffc the normal operation of the PSUs when they are directly connected. 5. Current sharing imbalance only in the normal temperature condition.

Hot Products

AC TO DC Power module output 1000W

AC TO DC Power module output 1000W

DC-DC converter 16 brick 36V~75V power module

DC-DC converter 16 brick 36V~75V power module

Power station intelligent Sub-Array Controller

Power station intelligent Sub-Array Controller

DC to DC power module input 60Vdc output 3000W

DC to DC power module input 60Vdc output 3000W

4.3inch TFT LCD 480*272 Resolution LCD module

4.3inch TFT LCD 480*272 Resolution LCD module

Smart Battery Cluster Controller for storage system

Smart Battery Cluster Controller for storage system

Rj45 Wall Mounted Android Touchscreen Wired And Wireless Compatible with 7inch display

Rj45 Wall Mounted Android Touchscreen Wired And Wireless Compatible with 7inch display

7inch TFT LCD module

7inch TFT LCD module

RJ45 Wall mounted Android Touchscreen wired and wireless compatible

RJ45 Wall mounted Android Touchscreen wired and wireless compatible

Intelligent Energy Storage Controller

Intelligent Energy Storage Controller

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours